Product features:
1.The product is with easy installation and can be used on the mainboard with terminals directly.
2.Iternational Universal input voltage: 85-264V AC or 110-370V DC.
3.The product has high efficiency with long use, high power density ,100% full load aging and high output voltage accuracy to 1%.
4.High isolation between input and output which adapt to Wide Environment Temperature – 25 – 70 degrees (CE Safety Standard with 40 degrees)
5.Types of protection: overcurrent protection, short circuit protection and temperature protection. Natural cooling has no noise and with long life.
6.Output built-in 105 degree with long life electrolytic capacitor.
7.The product meets to CE safety standard design, no load less than 0.1W, and with 75% Efficiency.
8.Ultra-low standby, six-level energy efficiency, ultra-thin design, three years of quality assurance.
Item |
Condition |
Common models of this series we have (we can customize any products with different output voltage and current or other requirements according to customer’s requirements ) | |||||
QLA03A-0505 | QLA03A-0512 | QLA03A-0524 | |||||
1 、Input Features |
|||||||
Working Voltage Range(VAC) | 85-264 | ||||||
Frequency Range(Hz) | 47-63 | ||||||
AC Input(VAC) | 85-264 | ||||||
DC Input(VDC) | 110-264 | ||||||
Input Current(mA) | 0.07/ 115VAC 0.03/230VAC | ||||||
Surge current(A) | Cold Boot:10A/230VAC | ||||||
Efficiency(TYP .) | 68% | 70% | 70% | ||||
Stand-by power consumption(mW) | ≤ 100mW | ||||||
2 、Output Features |
|||||||
Output Voltage(VDC) | Main Circuit 5V | Subcircuit 5V | Main Circuit5V | Subcircuit 12V | Main Circuit5V | Subcircuit 24V | |
Output voltage accuracy | Dual-Channel ± 1% | ||||||
Rated current(ADC) | V01:0.4A | V02:0.2A | V01:0.24A | V02:0. 15A | V01:0. 12A | V02:0. 1A | |
Rated power (W) | 3W | 3W | 3W | ||||
Ripple&Noise
(mvp-p) |
Rated input
voltage , 20MHz bandwidth |
≤50mV | ≤ 100mV |
Linear adjustment rate | Full-load | ± 1% |
Load regulation | 10- 100% Load | ±3% |
Startup and rise time | Full-load | 2000ms, 30ms/ 115VAC 1000ms, 30ms/230VAC |
Retention
time(ms) |
Full-load | 16ms/ 115VAC 50ms/230VAC |
Overload
protection |
Rated input voltage | 115%- 150% of the rated output power(Overload Protection ) |
Protection mode: hiccup mode, auto-response after removal of abnormal loading condition | ||
Short-circuit protection |
Rated input voltage |
Automatic recovery after long-term short circuit |
Over-current protection | ≥ 1.5 times Io | |
Start delay
time(ms) |
Vin :230VAC |
|
Power-off
protection time (ms) |
20ms |
|
3 、General Features |
||
Working temperature(℃) | / | -25-70 |
Working humidity
(RH) |
/ | 20-90%, non-condensing |
Temperature drift coefficient | / | ±0.02%/℃ |
Storage temperature and humidity | -40~+85℃ 10-95%RH | |
Switching frequency (KHz) | 5-65 (Frequency Conversion Control Chip) | |
Isolation voltage
(VAC) |
Input-to-output, test lasted 60s ,≤
5mA |
3KV≤5mA 60S |
Insulation resistance(MΩ) | Input-to-output,
500VDC |
100 |
Leakage current(mA) | 500VDC | Input-to-output ≤ 1mA/RMS |
MTBF | @25℃ | >250000H |
Safety level | / | Adaptation :CLASS B |
Vibration
resistance |
/ | 10—500Hz 2G 10 minutes/cycle . 60 minutes each for X, Y and Z. |
Electro-magnetic compatibility | / | Adaptation :EN55022(CISPR22) Class B EN61000-3-2,-3 |
Remarks |
1. Except for special instructions , the parameters of this specification are measured at 230VAC input, rated load and 25℃.
2. Measurement of ripple and noise: Using a 12” twisted pair, and the terminal has two capacitors , 0. 1uF and 10uF in parallel . Measured at 20MHz bandwidth . 3. Accuracy: Including errors, linear adjustment rate and load adjustment rate . 4. The power supply should be regarded as part of the components in the system, and electro-magnetic compatibility related confirmation should be carried out with the terminal equipment . 5. Reduced output is required under low input voltage . Please refer to the reduction graph. |
EMC Circuit Recommendation
Application schematic diagram
Product selection and Notes:
1.Please refer to the specifications in detail for selection and use, otherwise the reliability of power supply will not be guaranteed.
2.All parameters of this specification are measured according to the internal standards of our company.
3.It is suggested that the load power of the power supply should not exceed 80% of the rated power of the power supply.
4.With multi-output power supply, each output circuit must be loaded and used at the same time according to the corresponding ratio.
5.Our company can provide customized products.
6.We reserve the right to change specifications without prior notice.