Features:
- Input Voltage: 100-240VAC
- Power Range:12-60W
- High Eficiency: up to 89% ; PF>0.6
- P20 Design; Flicker-free
- Cooling by free air convection
- Suitable for dry or damp location use
- Protection:short circuit/over loading/over current/ Over temperature
- 3 years warranty
MODEL | QXP-LD-1201000 | QXP-LD-240500 | QXP-LD-1202000 | QXP-LD-2401000 | QXP-LD-1203000 | QXP-LD-2401500 | QXP-LD-1205000 | QXP-LD-2402500 | ||||||||||
OUTPUT | DC Voltage | 12V | 24V | 12V | 24V | 12V | 24V | 12V | 24V | |||||||||
Rated Current | 1A | 0.5A | 2A | 1A | 3A | 1.5A | 5A | 2.5A | ||||||||||
Rated Power | 12W | 24W | 36W | 60W | ||||||||||||||
Voltage Tolerance | +/-0.5V | |||||||||||||||||
Start-up Time (Typ.) | <500ms | |||||||||||||||||
INPUT | Voltage Range | 100 – 240VAC | ||||||||||||||||
Frequency Range | 50/60Hz | |||||||||||||||||
AC Current (Typ.) | 0.3A | 0.3A | 1A | 1A | 1A | 1A | 1.2A | 1.2A | ||||||||||
Efficiency (Typ.) | 84% | 87% | 87% | 88% | 88% | 88% | 90% | 91% | ||||||||||
Power Factor (Typ.) | <0.60c @ 120VAC and full load | |||||||||||||||||
Inrush Current (Typ.) | 29A / 120VAC | 35A / 120VAC | 36A / 120VAC | 38A / 120VAC | ||||||||||||||
Leakage current | <0.5mA / 120VAC | |||||||||||||||||
GUARDS | Over Current | Hiccup mode, auto-recovery upon removal of fault condition | ||||||||||||||||
Short Circuit | Hiccup mode, auto-recovery upon removal of fault condition | |||||||||||||||||
ENVIRO. | Ta | 4°F (-20°C) to 104°F (40°C) | ||||||||||||||||
Working Humidity | 20 – 90% Relative Humidity, non-condensing | |||||||||||||||||
Storage Temp. & RH | -40°F (-40°C) to 176°F (80°C), 10 – 95% Relative Humidity | |||||||||||||||||
Vibration | 10 – 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes | |||||||||||||||||
OTHER | MTBF | 292K hrs min. | 318K hrs min. | 308K hrs min. | 300K hrs min. | |||||||||||||
Cooling | Free Air Convection | |||||||||||||||||
Life Time* | 50,000 hours | |||||||||||||||||
Case | Fully isolated polycarbonate plastic case with built in terminal block for direct-wire connections | |||||||||||||||||
Dimensions | (80mm L x 33mm W x 21mm H) | (100mm L x 43mm W x 21mm H) | (100mm L x 43mm W x 21mm H) | (130mm L x43mm W x 21mm H) |
Protection | Short Circuit | Hiccup mode, recover automatically after fault condition is removed |
Over Current | ≤1.2*| out | |
Over Loading | ≤120% | |
Over temperature | 100°C士10°C,Shut down o/p voltage,recover automatically after temperature goes down. | |
Safety& EMC | Safety standards | EN61347-1 EN61347-2-13 UL Std. 8750, CAN/CSA Std. C22.2 No. 250.13; Class 2 Power Supply, ETL Listed for dry and damp location use,EN61347-1 EN61347-2-13 |
Withstand voltage | I/P-O/P:3KVAC IP-FG:1.88KVAC O/P-FG:0.5KVAC | |
Isolation resistance | I/P-O/P I/P-FG O/P-FG:100MΩ/500VDC/25*C/70%RH | |
EMC EMISSION | EN55022, EN55015 Class B | |
Notes | 1. All parameters if NOT specially mentioned are measured at 120VAC input , rated load and 25°C of ambient temperature.2. To extend the driver’s using life ,please reduce the loading at lower input voltage |
Dimensions
12W 24-36W 60W
Warning
※Prevent to reverse polarity;
※Risk of Electric Shock. When used outdoors, install only on a circuit protected by a Class A GFCI;
※Risk of Fire. Istallation involves special wiring methods to run wiring through a building structure. Consult a qualified electrician;
※Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface.