Product features:
1.The product is with easy installation. Input / Output could insert terminals and Retainable hole welding wire is used.
2.Fixed mounting holes are arranged at the four corners to prevent from power failure due to movement/vibration. The straight length of the fixed holes is 3.2mm.
3.Iternational Universal input voltage: 85-264V AC or 110-370V DC.
4.High efficiency, high power density, low output ripple noise, dual channel output,High accuracy of output voltage of control circuit (+5V/7V)
5.High isolation between input and output
6.Overcurrent protection, short circuit protection and temperature protection.
7.The output has built-in double LC-pi filter without external circuit.
8.Three years of quality assurance
Item |
Condition |
Common models of this series we have (we can customize any products with different output voltage and current
or other requirements according to customer’s requirements) |
|||||
QLK17W-0512 | QLK17W-0524 | QLK17W-0712 | |||||
1 、Input Features | |||||||
AC Input(VAC) | 85-264VAC | ||||||
DC Input(VDC) | 110-370VDC | ||||||
Frequency Range(Hz) | 47-63Hz | ||||||
Input Current(A) | 1/ 115VAC 0.5/230VAC | ||||||
Surge current(A) | Cold Boot:20A/230VAC | ||||||
Efficiency(TYP.) | 76% | 78% | 81% | ||||
Stand-by power consumption(mW) | ≤300mW/230VAC | ||||||
2 、Output Features | |||||||
Output Voltage(VDC) | 5V+ 12V | 5V+24V | 7V+ 12V | ||||
Output voltage accuracy | Main Circuit:± 1% ,Subcircuit :± 10% | ||||||
Rated current(ADC) | 1A | 1A | 1A | 0.5A | 0.7A | 1A | |
Rated power(W) | 17W | 17W | 17W | ||||
Ripple&Noise(mv
p-p) |
Rated input
voltage, 20MHz bandwidth |
VO1 Main Circuit:5V/7V- 100mV | |||||
VO2 Subcircuit: 12V/24V-200mV | |||||||
Linear adjustment rate | Full-load | ± 1% | |||||
Load regulation | 10- 100% Load | ±3% | |||||
Start up and rise time | Full-load | 2000ms ,30ms/ 115VAC 1000ms ,30ms/230VAC | |||||
Retention
time(ms) |
Full-load | 16ms/ 115VAC 50ms/230VAC | |||||
Overload
protection |
Rated input voltage | 115%- 150% of the rated output power | |||||
Protection mode: hiccup mode, auto-response after removal of abnormal | |||||||
Short-circuit protection |
Rated input voltage |
Automatic recovery after long-term short circuit | |||||
Over-current protection | ≥ 1. 1 times Io |
Start delay
time(ms) |
Vin :230VAC |
500ms |
Power-off
protection time(ms) |
20ms | |
3 、General Features | ||
Working temperature(C) | / | -30-70C |
Working humidity(RH) | / | 20-90%RH ,non-condensing |
temperature
coefficient |
/ | ±0.02%/C |
Storage temperature and humidity | -40~+85C 10-95%RH | |
Switching frequency(KHz) | 20-65KHz | |
Isolation voltage(VAC) | Input-to-output, test lasted 60s ,≤
5mA |
3000VAC |
Insulation resistance(MΩ) | Input-to-output,
500VDC |
100MΩ |
Leakage current(mA) | 500VDC | Input to output ≤ 1mA/RMS |
MTBF | @25C | 215000h |
Safety level | / | Adaptation :CLASS B |
Vibration
resistance |
/ | 10—500Hz 2G 10 minutes/cycle. 60 minutes each for X, Y and Z. |
Electro-magnetic compatibility | / | Adaptation :EN55022(CISPR22) Class B EN61000-3-2-3 |
Remarks |
1. Except for special instructions,the parameters of this specification are measured at 230VAC input, rated load and 25C.
2. Measurement of ripple and noise: Using a 12” twisted pair,and the terminal has two capacitors, 0. 1uF and 10uF in parallel. Measured at 20MHz bandwidth. 3.Accuracy: Including errors, linear adjustment rate and load adjustment rate. 4. The power supply should be regarded as part of the components in the system, and electro-magnetic compatibility related confirmation should be carried out with the terminal equipment. 5. Reduced output is required under low input voltage.Please refer to the reduction graph. |
Product Packaging and Pin Definition Diagram
Product selection and Notes:
1.Please refer to the specifications in detail for selection and use, otherwise the reliability of power supply will not be guaranteed.
2.All parameters of this specification are measured according to the internal standards of our company.
3.It is suggested that the load power of the power supply should not exceed 80% of the rated power of the power supply.
4.With multi-output power supply, each output circuit must be loaded and used at the same time according to the corresponding ratio. The maximum current of high precision voltage (5V) group of this series of products is 1A, and more than 1A will cause permanent damage to the products.
5.Our company can provide customized products.
6.We reserve the right to change specifications without prior notice.