1.Fixed mounting holes are arranged at the four corners to prevent from power failure due to movement/vibration. The straight length of the fixed holes is 3.2mm.
2.Iternational Universal input voltage: 85-264V AC or 110-370V DC.
3.High efficiency, high power density, low output ripple noise, dual channel output,High accuracy of output voltage of control circuit (+5V/7V)
4.High isolation between input and output
5.Overcurrent protection, short circuit protection and temperature protection.
6.The output has built-in double LC-pi filter without external circuit.
7.Three years of quality assurance
Item | Condition | Common models of this series we have (we can customize any products with different output voltage and current
or other requirements according to customer’s requirements) |
|||||
QLA17A-0505 | QLA17A- 1212 | QLA17A- 1515 | |||||
1 、Input Features | |||||||
AC Input(VAC) | 85-264VAC | ||||||
DC Input(VDC) | 110-370VDC | ||||||
Frequency Range(Hz) | 47-63Hz | ||||||
Input Current(A) | 1/ 115VAC 0.5/230VAC | ||||||
Surge current(A) | Cold Boot:20A/230VAC | ||||||
Efficiency(TYP.) | 69% | 78% | 76% | ||||
Stand-by power consumption(mW) | ≤ 1W/230VAC | ||||||
2 、Output Features | |||||||
Output Voltage(VDC) | ±5V | ± 12V | ± 15V | ||||
Output voltage accuracy | Main Circuit:± 1% ,Subcircuit :± 10% | ||||||
Rated current(ADC) | 1.7A | 1.7A | 0.7A | 0.7A | 0.55A | 0.55A | |
Rated power(W) | 17W | 17W | 17W | ||||
Ripple&Noise(mv
p-p) |
Rated input
voltage, 20MHz bandwidth |
VO1(V+)Main Circuit:50mV | |||||
VO2(V-)Subcircuit :100mV | |||||||
Linear adjustment rate | Full-load | ± 1% | |||||
Load regulation | 10- 100% Load | ±3% | |||||
Start up and rise time | Full-load | 2000ms ,30ms/ 115VAC 1000ms ,30ms/230VAC | |||||
Retention
time(ms) |
Full-load | 16ms/ 115VAC 50ms/230VAC | |||||
Overload
protection |
Rated input voltage | 115%- 150% of the rated output power | |||||
Protection mode: hiccup mode, auto-response after removal of abnormal | |||||||
Short-circuit protection |
Rated input voltage |
Automatic recovery after long-term short circuit | |||||
Over-current protection | ≥ 1. 1 Times Io |
Start delay
time(ms) |
Vin :230VAC |
500ms |
Power-off
protection time(ms) |
20ms |
|
3 、General Features | ||
Working temperature(C) | / | -30-70C |
Working humidity(RH) | / | 20-90% ,RH non-condensing |
temperature
coefficient |
/ | ±0.02%/C |
Storage temperature and humidity | -40~+85C 10-95%RH | |
Switching frequency(KHz) | 20-65KHz | |
Isolation voltage(VAC) | Input-to-output, test lasted 60s ,≤
5mA |
3000VAC |
Insulation resistance(MΩ) | Input-to-output,
500VDC |
100MΩ |
Leakage current(mA) | 500VDC | Input to output ≤ 1mA/RMS |
MTBF | @25C | 215000h |
Safety level | / | Adaptation :CLASS B |
Vibration
resistance |
/ | 10—500Hz 2G 10 minutes/cycle. 60 minutes each for X, Y and Z |
Electro-magnetic compatibility | / | Adaptation :EN55022(CISPR22) Class B EN61000-3-2-3 |
Remarks |
1. Except for special instructions, the parameters of this specification are measured at 230VAC input, rated load and 25C.
2. Measurement of ripple and noise: Using a 12” twisted pair, and the terminal has two capacitors, 0. 1uF and 10uF in parallel. Measured at 20MHz bandwidth. 3.Accuracy: Including errors, linear adjustment rate and load adjustment rate. 4. The power supply should be regarded as part of the components in the system, and electro-magnetic compatibility related confirmation should be carried out with the terminal equipment. 5. Reduced output is required under low input voltage. Please refer to the reduction graph. |
>Input Parts: | ||
Original Bit Number/Recommended Device | Effects | Recommended values
(Regular ) |
FUSE | When the product is abnormal, protect the whole circuit from damage | 2.0A/250VAC,Slow fuse (must be connected) |
MOV | Varistor, lightning protection | 14D561K (Optional) |
NTC |
Negative temperature coefficient thermistor, lightning protection and surge current protection | 10D11 (Optional) |
Remarks :
(1) The conventional model of this product can resist lightning stroke 1KV,IEC61000-4-2 Class B and no need to add additional
varistor and thermistor.
(2) This special product can resist lightning strike 4KV,IEC61000-4-2 Class B ,and no need to add additional varistor and thermistor.
(3) With using this product, if lightning strike is above 4KV, then you need to add varistor and thermistor, or customize it.