Product features:
1.The product is with easy installation . Input / Output could insert terminals and Retainable hole welding wire is used.
2.Fixed mounting holes are arranged at the four corners to prevent from power failure due to movement/vibration . The straight length of the fixed holes is 3.2mm.
3.Iternational Universal input voltage: 85-264V AC or 110-370V DC .
4.High efficiency, high power density, low output ripple noise, dual channel output,High accuracy of output voltage of control circuit (+5V/7V)
5.High isolation between input and output
6.Overcurrent protection , short circuit protection and temperature protection .
7.The output has built-in double LC-pi filter without external circuit .
8.Three years of quality assurance
Item |
Condition |
Common models of this series we have (we can customize any products with different output voltage and current
or other requirements according to customer’s requirements ) |
|||||
QLL17A-0512 | QLL17A-0524 | QLL17A-0712 | |||||
1 、Input Features | |||||||
AC Input(VAC) | 85-264VAC | ||||||
DC Input(VDC) | 110-370VDC | ||||||
Frequency Range(Hz) | 47-63Hz | ||||||
Input Current(A) | 1/ 115VAC 0.5/230VAC | ||||||
Surge current(A) | Cold Boot:20A/230VAC | ||||||
Efficiency(TYP .) | 76% | 78% | 81% | ||||
Stand-by power consumption(mW) | ≤200mW/230VAC | ||||||
2 、Output Features | |||||||
Output Voltage(VDC) | 5V+ 12V | 5V+24V | 7V+ 12V | ||||
Output voltage accuracy | Main Circuit :± 1% ,Subcircuit :± 10% | ||||||
Rated current(ADC) | 0.6A | 1.2A | 0.6A | 0.6A | 0.5A | 1.2A | |
Rated power(W) | 17W | 17W | 17W | ||||
Ripple&Noise(mv
p-p) |
Rated input
voltage , 20MHz bandwidth |
VO1 Main Circuit:5V/7V- 100mV | |||||
VO2 Subcircuit: 12V/24V-200mV | |||||||
Linear adjustment rate | Full-load | ± 1% | |||||
Load regulation | 10- 100% Load | ±3% | |||||
Start up and rise time | Full-load | 2000ms ,30ms/ 115VAC 1000ms , 30ms/230VAC | |||||
Retention
time(ms) |
Full-load | 16ms/ 115VAC 50ms/230VAC | |||||
Overload
protection |
Rated input voltage | 115%- 150% of the rated output power | |||||
Protection mode: hiccup mode, auto-response after removal of abnormal |
Short-circuit protection |
Rated input voltage |
Automatic recovery after long-term short circuit |
Over-current protection | ≥ 1. 1 times Io | |
Start delay
time(ms) |
Vin :230VAC |
500ms |
Power-off
protection time(ms) |
20ms |
|
3 、General Features | ||
Working temperature(C) | / | -30-70C |
Working humidity(RH) | / | 20-90% ,RH non-condensing |
temperature
coefficient |
/ | ±0.02%/C |
Storage temperature and humidity | -40~+85C 10-95%RH | |
Switching frequency(KHz) | 20-65KHz | |
Isolation voltage(VAC) | Input-to-output, test lasted 60s ,≤
5mA |
3000VAC |
Insulation resistance(MΩ) | Input-to-output,
500VDC |
100MΩ |
Leakage current(mA) | 500VDC | Input to output ≤ 1mA/RMS |
MTBF | @25C | 215000h |
Safety level | / | Adaptation :CLASS B |
Vibration
resistance |
/ | 10—500Hz 2G 10 minutes/cycle . 60 minutes each for X, Y and Z. |
Electro-magnetic compatibility | / | Adaptation :EN55022(CISPR22) Class B EN61000-3-2-3 |
Remarks |
1. Except for special instructions , the parameters of this specification are measured at 230VAC input, rated load and 25C.
2. Measurement of ripple and noise: Using a 12” twisted pair, and the terminal has two capacitors , 0. 1uF and 10uF in parallel . Measured at 20MHz bandwidth . 3.Accuracy: Including errors, linear adjustment rate and load adjustment rate . 4. The power supply should be regarded as part of the components in the system, and electro-magnetic compatibility related confirmation should be carried out with the terminal equipment . 5. Reduced output is required under low input voltage . Please refer to the reduction graph. |
Product Packaging and Pin Definition Diagram
Product selection and Notes:
1.Please refer to the specifications in detail for selection and use, otherwise the reliability of power supply will not be guaranteed .
2.All parameters of this specification are measured according to the internal standards of our company.
3.It is suggested that the load power of the power supply should not exceed 80% of the rated power of the power supply.
4.With multi-output power supply, each output circuit must be loaded and used at the same time according to the corresponding ratio . The maximum current of high precision voltage (5V) group of this series of products is 1A, and more than 1A will cause permanent damage to the products .
5.Our company can provide customized products . 6.We reserve the right to change specifications without prior notice